To better understand the mechanisms underpinning work-related neck pain, this cross-sectional and single-blinded study compared somatosensory...
Array
(
[id_prestablog_news] => 1539
[id_shop] => 1
[date] => 2022-08-01 00:00:00
[date_modification] => 2024-02-09 14:15:13
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 3279
[id_lang] => 1
[title] => Enhanced pain facilitation rather than impaired pain inhibition in burning mouth
[paragraph] => Enhanced pain facilitation rather than impaired pain inhibition in burning mouth syndrome female patients
[content] => Authors
Y Xie, L Thomas, M Barbero et al
Lab
The University of Queensland, QLD, Australia
Journal
Pain
Abstract
To better understand the mechanisms underpinning work-related neck pain, this cross-sectional and single-blinded study compared somatosensory profiles among sonographers with varied neck disability levels. Based on K-mean cluster analysis of scores on the neck disability index (NDI), participants were classified into no (NDI ≤ 8%, n = 31, reference group), mild (NDI = 10%-20%, n = 43), or moderate/severe (NDI ≥ 22%, n = 18) disability groups. Data were collected on bodily pain distribution and severity and psychological measures including depression, anxiety, pain-catastrophizing, and fear-avoidance beliefs using validated scales. Participants attended 1 session of quantitative sensory testing performed according to a standardized protocol, including local and remote thermal and mechanical pain thresholds, temporal summation of pain (TSP), conditioned pain modulation, and an exercise-induced analgesia paradigm. Compared with participants with no and mild disability, those with moderate/severe disability showed more widespread pain, cold and mechanical hyperalgesia at a remote nonpainful site, and significantly higher TSP. Participants with mild disability demonstrated significantly higher TSP than those with no disability. These group differences were attenuated after adjusting for depression or anxiety, indicating these psychological factors may mediate the somatosensory changes associated with neck disability. Group differences were not found for conditioned pain modulation or exercise-induced analgesia. These findings suggest that heightened pain facilitation, rather than impaired pain inhibition may underpin nociplastic pain in participants with moderate/severe disability, and it may be associated with depression and anxiety. Clinicians should be aware that individuals with work-related neck pain presenting with moderate/severe disability display distinct somatosensory features and tailor management strategies accordingly.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
[meta_description] =>
[meta_keywords] => https://doi.org/10.1097/j.pain.0000000000002213
[meta_title] =>
[link_rewrite] => enhanced-pain-facilitation-rather-than-impaired-pain-inhibition-in-burning-mouth-syndrome-female-patients
[actif_langue] => 1
[read] => 1014
[count_comments] => 0
[id] => 1539
[categories] => Array
(
[27] => Array
(
[id_prestablog_categorie] => 27
[title] => General pain
[link_rewrite] => General-pain
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Enhanced pain facilitation rather than impaired pain inhibition in burning mouth syndrome [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Electronic Von Frey - Wireless
[description_short] => A quick solution to determine the mechanical sensitivity threshold in rodents (mice and rats). Now wireless, to be free from annoying cables!
This precise and easy-to-use electronic instrument is a must-have reference for your research in analgesia, nociception, neuro-pathologies and post-operative pain.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://preprod.bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Electronic Von Frey 5 with embedded camera
[description_short] => As an electronic version of the classical Von Frey Filaments esthesiometer (or aesthesiometer), the latest evolution of Bioseb's Electronic Von Frey instrument for determining the mechanical sensitivity threshold in rodents (rats and mice) is a must-have instrument for your reseach on hyperalgesia and allodynia. By measuring and recording the force at which the animal exhibits a paw withdrawal reflex, pathologies related to sensory response and hyper- or hypo-aesthesia can be studied.
The EVF5 includes an embedded camera inside the stimulator handle and a new, dedicated software revolutionizing the experimental process.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://preprod.bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 Read more