Publications

Latest publication 08/01/2010

Effect of sildenafil on the anticonvulsant action of classical and second-genera

PURPOSE: The goal of the present study was to evaluate the effects of sildenafil on the threshold for electrically induced seizures in mice. In...

Array
(
    [id_prestablog_news] => 268
    [id_shop] => 1
    [date] => 2010-08-01 00:00:00
    [date_modification] => 2024-02-09 14:15:11
    [langues] => ["1","2"]
    [actif] => 1
    [slide] => 0
    [url_redirect] => 
    [average_rating] => 
    [number_rating] => 
    [author_id] => 1
    [featured] => 0
    [prim_key] => 533
    [id_lang] => 1
    [title] => Effect of sildenafil on the anticonvulsant action of classical and second-genera
    [paragraph] => Effect of sildenafil on the anticonvulsant action of classical and second-generation antiepileptic drugs in maximal electroshock-induced seizures in mice. 
    [content] => 

Authors
D. Nieoczym, J. _uszczki, S. Czuczwar, P. Wlaz.


Lab
Maria Curie-Sk_odowska University, Institute of Biology, Department of Animal Physiology, Lublin, Poland.

Journal
Epilepsia

Abstract
PURPOSE: The goal of the present study was to evaluate the effects of sildenafil on the threshold for electrically induced seizures in mice. In addition, interactions between sildenafil and classical and second-generation antiepileptic drugs (AEDs), that is, carbamazepine (CBZ), phenobarbital (PB), phenytoin (PHT), valproate (VPA), lamotrigine (LTG), topiramate (TPM), and oxcarbazepine (OXC) were evaluated. METHODS: Two electroconvulsive tests were used: maximal electroshock seizure threshold (MEST) and maximal electroshock seizure (MES) tests in mice. Acute adverse effects of the studied combinations were investigated in the chimney test, step-through passive avoidance task, and grip-strength test. Total brain and free plasma concentrations of AEDs were also determined. RESULTS: Sildenafil raised the threshold for electroconvulsions in a dose-dependent manner. It also increased the anticonvulsant activity of CBZ, VPA, and TPM in the MES test, whereas the activity of the remaining AEDs was not significantly changed. Sildenafil increased total brain and free (protein unbound) plasma CBZ concentrations and total brain VPA concentration. Neither sildenafil nor its coadministration with the studied AEDs affected motor coordination and long-term memory in mice. Interestingly, sildenafil dose-dependently enhanced the skeletal muscle strength in mice, although combinations of sildenafil with AEDs were ineffective in this respect. CONCLUSIONS: Sildenafil significantly raised the threshold for electroconvulsions in mice without any impairment of motor performance and long-term memory, but it enhanced muscle strength. Treatment of patients on CBZ or VPA with sildenafil may not be recommended due to pharmacokinetic interactions. Coadministration of sildenafil with other AEDs, especially with TPM, seems to be a reasonable choice.

BIOSEB Instruments Used
Grip strength test (BIO-GS3)

[meta_description] => [meta_keywords] => http://onlinelibrary.wiley.com/doi/10.1111/j.1528-1167.2009.02485.x/abstract;jsessionid=C1ED4B84F6B5C2293C790AE7E2282734.d01t01 [meta_title] => [link_rewrite] => effect-of-sildenafil-on-the-anticonvulsant-action-of-classical-and-second-generation-antiepileptic-drugs-in-maximal-electroshock-induced-seizures-in-mice-- [actif_langue] => 1 [read] => 1071 [count_comments] => 0 [id] => 268 [categories] => Array ( [11] => Array ( [id_prestablog_categorie] => 11 [title] => Central Nervous System (CNS) [link_rewrite] => Central-Nervous-System-(CNS) ) [41] => Array ( [id_prestablog_categorie] => 41 [title] => Epilepsy [link_rewrite] => Epilepsy ) [2] => Array ( [id_prestablog_categorie] => 2 [title] => Publications [link_rewrite] => publications ) ) [authors] => [paragraph_crop] => Effect of sildenafil on the anticonvulsant action of classical and second-generation [...] [link_for_unique] => 1 [products_liaison] => Array ( [48] => Array ( [name] => Grip strength test [description_short] =>

An easy way to objectively quantify the muscular strength of mice and rats, and to assess the effect of drugs, toxins, muscular (i.e. myopathy) and neurodegenerative diseases on muscular degeneration. It is widely used in conjunction with the ROTAROD motor coordination test: a normally coordinated rodent will show a decreased latency to fall off the rotating rod if its muscular strength is low. The Grip Strength Test is a must for your research on activity, motor control & coordination, and is particularly well suited for studies on Parkinson's & Huntington's disease.

New features GS4 - 2023: Color display with permanent backlight screen for easier reading, reset by footswitch, Improved battery time, Larger data memory of 500 values, Animal counter, USB port (charging/data transfer)

forrats.pngformice.png

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://preprod.bioseb.com/en/activity-motor-control-coordination/48-grip-strength-test.html ) ) ) 1
Read more

Filters

Applications

Dates