General pain - page 2 Scientific Publications

Latest publication 03/19/2020

Dim light at night exposure induces cold hyperalgesia and mechanical allodynia i

The growing presence of artificial lighting across the globe presents a number of challenges to human and ecological health despite its societal...

Array
(
    [id_prestablog_news] => 1249
    [id_shop] => 1
    [date] => 2020-03-19 00:00:00
    [date_modification] => 2024-02-09 14:15:12
    [langues] => ["1","2"]
    [actif] => 1
    [slide] => 0
    [url_redirect] => 
    [average_rating] => 
    [number_rating] => 
    [author_id] => 1
    [featured] => 0
    [prim_key] => 2455
    [id_lang] => 1
    [title] => Dim light at night exposure induces cold hyperalgesia and mechanical allodynia i
    [paragraph] => Dim light at night exposure induces cold hyperalgesia and mechanical allodynia in male mice
    [content] => 

Authors
JR Bumgarner, WH Walker II, JA Liu et al


Lab
Department of Neuroscience, Rockefeller Neuroscience Institute, West Virginia University, Morgantown, WV, USA

Journal
Neuroscience

Abstract
The growing presence of artificial lighting across the globe presents a number of challenges to human and ecological health despite its societal benefits. Exposure to artificial light at night, a seemingly innocuous aspect of modern life, disrupts behavior and physiological functions. Specifically, light at night induces neuroinflammation, which is implicated in neuropathic and nociceptive pain states, including hyperalgesia and allodynia. Because of its influence on neuroinflammation, we investigated the effects of dim light at night exposure on pain responsiveness in male mice. In this study, mice exposed to four days of dim (5_lux) light at night exhibited cold hyperalgesia. Further, after 28_days of exposure, mice exhibited both cold hyperalgesia and mechanical allodynia. No heat/hot hyperalgesia was observed in this experiment. Altered nociception in mice exposed to dim light at night was concurrent with upregulated interleukin-6 and nerve growth factor mRNA expression in the medulla and elevated micro-opioid receptor mRNA expression in the periaqueductal gray region of the brain. The current results support the relationship between disrupted circadian rhythms and altered pain sensitivity. In summary, we observed that dim light at night induces cold hyperalgesia and mechanical allodynia, potentially through elevated neuroinflammation and dysregulation of the endogenous opioid system.

BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)

[meta_description] => [meta_keywords] => https://www.sciencedirect.com/science/article/abs/pii/S030645222030172X [meta_title] => [link_rewrite] => dim-light-at-night-exposure-induces-cold-hyperalgesia-and-mechanical-allodynia-in-male-mice [actif_langue] => 1 [read] => 1344 [count_comments] => 0 [id] => 1249 [categories] => Array ( [27] => Array ( [id_prestablog_categorie] => 27 [title] => General pain [link_rewrite] => General-pain ) [10] => Array ( [id_prestablog_categorie] => 10 [title] => Pain [link_rewrite] => Pain ) [2] => Array ( [id_prestablog_categorie] => 2 [title] => Publications [link_rewrite] => publications ) ) [authors] => [paragraph_crop] => Dim light at night exposure induces cold hyperalgesia and mechanical allodynia in male mice [link_for_unique] => 1 [products_liaison] => Array ( [1859] => Array ( [name] => Electronic Von Frey - Wireless [description_short] =>

A quick solution to determine the mechanical sensitivity threshold in rodents (mice and rats). Now wireless, to be free from annoying cables!

This precise and easy-to-use electronic instrument is a must-have reference for your research in analgesia, nociception, neuro-pathologies and post-operative pain.

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://preprod.bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1859-electronic-von-frey-4.html ) [1860] => Array ( [name] => Electronic Von Frey 5 with embedded camera [description_short] =>

As an electronic version of the classical Von Frey Filaments esthesiometer (or aesthesiometer), the latest evolution of Bioseb's Electronic Von Frey instrument for determining the mechanical sensitivity threshold in rodents (rats and mice) is a must-have instrument for your reseach on hyperalgesia and allodynia. By measuring and recording the force at which the animal exhibits a paw withdrawal reflex, pathologies related to sensory response and hyper- or hypo-aesthesia can be studied.

The EVF5 includes an embedded camera inside the stimulator handle and a new, dedicated software revolutionizing the experimental process.

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://preprod.bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1860-electronic-von-frey-5-with-embedded-camera.html ) ) ) 1
Read more

Filters

Applications

Dates

<< 1 ... 2 3 4 5 6 >>