The foreign body reaction (FBR) against an implanted device is characterized by the formation of a fibrotic tissue around the implant. In the case...
Array
(
[id_prestablog_news] => 942
[id_shop] => 1
[date] => 2017-11-18 00:00:00
[date_modification] => 2024-02-09 14:15:12
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 1848
[id_lang] => 2
[title] => Time course study of long-term biocompatibility and foreign body reaction to int
[paragraph] => Time course study of long-term biocompatibility and foreign body reaction to intraneural polyimide-based implants
[content] => Authors
N de la Oliva, X Navarro, J de Valle
Lab
Institute of Neurosciences, Bellaterra, Barcelona, Spain
Journal
Journal of Biomedical Materials Research
Abstract
The foreign body reaction (FBR) against an implanted device is characterized by the formation of a fibrotic tissue around the implant. In the case of interfaces for peripheral nerves, used to stimulate specific group of axons and to record different nerve signals, the FBR induces a matrix deposition around the implant creating a physical separation between nerve fibers and the interface that may reduce its functionality over time. In order to understand how the FBR to intraneural interfaces evolves, polyimide non-functional devices were implanted in rat peripheral nerve. Functional tests (electrophysiological, pain and locomotion) and histological evaluation demonstrated that implanted devices did not cause any alteration in nerve function, in myelinated axons or in nerve architecture. The inflammatory response due to the surgical implantation decreased after 2 weeks. In contrast, inflammation was higher and more prolonged in the device implanted nerves with a peak after 2 weeks. With regard to tissue deposition, a tissue capsule appeared soon around the devices, acquiring maximal thickness at 2 weeks and being remodeled subsequently. Immunohistochemical analysis revealed two different cell types implicated in the FBR in the nerve: macrophages as the first cells in contact with the interface and fibroblasts that appear later at the edge of the capsule. Our results describe how the FBR against a polyimide implant in the peripheral nerve occurs and which are the main cellular players. Increasing knowledge of these responses will help to improve strategies to decrease the FBR against intraneural implants and to extend their usability.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
[meta_description] =>
[meta_keywords] => http://onlinelibrary.wiley.com/doi/10.1002/jbm.a.36274/full
[meta_title] =>
[link_rewrite] => time-course-study-of-long-term-biocompatibility-and-foreign-body-reaction-to-intraneural-polyimide-based-implants
[actif_langue] => 1
[read] => 992
[count_comments] => 0
[id] => 942
[categories] => Array
(
[10] => Array
(
[id_prestablog_categorie] => 10
[title] => Douleur
[link_rewrite] => Douleur
)
[28] => Array
(
[id_prestablog_categorie] => 28
[title] => Douleurs inflammatoires
[link_rewrite] => Douleurs-inflammatoires
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Time course study of long-term biocompatibility and foreign body reaction to intraneural [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Von Frey Électronique - Sans Fil
[description_short] => Une solution rapide pour déterminer le seuil de sensibilité à la douleur mécanique chez les rongeurs (rats et souris). Maintenant en version sans-fil, pour être libéré des câbles!
Cet instrument électronique précis et simple d'utilisation est le test de référence pour vos recherches en analgésie, nociception, neuropathies et douleurs post-opératoires


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://preprod.bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Von Frey Électronique 5 avec caméra intégrée
[description_short] =>
En tant que version électronique du classique esthésiomètre à filaments de Von Frey, la dernière évolution de l’instrument électronique Von Frey de Bioseb, conçu pour déterminer le seuil de sensibilité mécanique chez les rongeurs (rats et souris) par stimulation sous la patte, est un outil indispensable pour vos recherches sur l’hyperalgésie et l’allodynie. En mesurant et en enregistrant la force à laquelle l’animal présente un réflexe de retrait de la patte, il est possible d’étudier les pathologies liées à la réponse sensorielle ainsi qu’à l’hyper- ou l’hypoesthésie.
L'EVF5 intègre une caméra embarquée au niveau de la zone de stimulation et fonctionne avec un nouveau logiciel dédié révolutionnaire


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://preprod.bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 En lire plus