Background Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is considered as a gold standard therapy for the alleviation of motor...
Array
(
[id_prestablog_news] => 1207
[id_shop] => 1
[date] => 2019-12-31 00:00:00
[date_modification] => 2024-02-09 14:15:12
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 2372
[id_lang] => 2
[title] => In vivo validation of a new portable stimulator for chronic deep brain stimulati
[paragraph] => In vivo validation of a new portable stimulator for chronic deep brain stimulation in freely moving rats
[content] => Authors
H Tibar, F Naudet, F Kölbl, B Ribot, E Faggiani et al
Lab
Institut des Maladies Neurodégénératives (IMN), CNRS UMR 5293, Centre Broca Nouvelle-Aquitaine, Université de Bordeaux, Bordeaux Cedex, France.
Journal
Journal of Neuroscience Methods
Abstract
BackgroundDeep brain stimulation (DBS) of the subthalamic nucleus (STN) is considered as a gold standard therapy for the alleviation of motor symptoms in Parkinson’s disease (PD). This success paved the way to its application for other neurological and psychiatric disorders. In this context, we aimed to develop a rodent-specific stimulator with characteristics similar to those used in patients.
New methodWe designed a stimulator that can be connected to an electrode container with options for bilateral or unilateral stimulation selection and offers a wide range of frequencies, pulse widths and intensities, constant current, biphasic current-control and charge balancing. Dedicated software was developed to program these parameters and the device was tested on a bilateral 6-hydroxydopamine (6-OHDA) rat model of PD.
Results The equipment was well tolerated by the animals with a good general welfare. STN stimulation (130 Hz frequency, 0.06 ms pulse width, 150 _A average intensity) improved the motor deficits induced by 6-OHDA as it significantly increased the number of movements compared to the values obtained in the same animals without STN stimulation. Furthermore, it restored motor coordination by significantly increasing the time spent on the rotarod bar.
Conclusion We successfully developed and validated a new portable and programmable stimulator for freely moving rats that delivers a large range of stimulation parameters using bilateral biphasic current-control and charge balancing to maximize tissue safety. This device can be used to test deep brain stimulation in different animal models of human brain diseases.
BIOSEB Instruments Used
Aron Test or Four Plates Test (LE830),Rotarod (BX-ROD)
[meta_description] =>
[meta_keywords] => https://www.sciencedirect.com/science/article/pii/S0165027019304340#!
[meta_title] =>
[link_rewrite] => in-vivo-validation-of-a-new-portable-stimulator-for-chronic-deep-brain-stimulation-in-freely-moving-rats
[actif_langue] => 1
[read] => 1022
[count_comments] => 0
[id] => 1207
[categories] => Array
(
[45] => Array
(
[id_prestablog_categorie] => 45
[title] => Maladie de Parkinson
[link_rewrite] => Maladie-de-Parkinson
)
[12] => Array
(
[id_prestablog_categorie] => 12
[title] => Neurodégénérescence
[link_rewrite] => Neurodegenerescence
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => In vivo validation of a new portable stimulator for chronic deep brain stimulation in freely [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[588] => Array
(
[name] => Test d'Aron ou 'Four Plates Test'
[description_short] => Le 'Four Plates Test' ou test d'Aron est une exclusivité Bioseb!
Un outil rapide pour l'évaluation de substances anxiolytiques putatives chez l'animal naïf. Un "must" pour l'étude de l'anxiété, le screening des drogues et le phénotypage.
[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://preprod.bioseb.com/fr/anxiete-depression/588-aron-test-or-four-plates-test.html
)
[1326] => Array
(
[name] => Rotarod pour rats et souris
[description_short] => Le Rotarod offre une méthode facile pour le test de l'activité motrice chez les rongeurs (rats ou souris) - une solution idéale pour étudier les lésions du système nerveux central (SNC), les effets de différentes pathologies et substances pharmacologiques sur l'activité motrice, la résistance à la fatigue, etc. Désormais encore plus simple d'utilisation! La nouvelle interface utilisateur graphique et tactile permet une visualisation claire de la vitesse et des temps associés à chaque piste. Vous pouvez maintenant changer de mode, régler la vitesse et créer des protocoles directement depuis l'écran principal for une une plus grande flexibilité et un maximum de fonctionnalités.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/preprod.bioseb.com/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://preprod.bioseb.com/fr/activite-systeme-moteur-coordination/1326-rotarod.html
)
)
)
1 En lire plus